HAS Panel Mount Current Transducers

LEM HAS Panel Mount Current Transducers provide a reliable solution for electronic measurement of DC, AC, and pulsed currents while ensuring galvanic isolation between the primary and secondary circuits. Utilizing open-loop Hall effect technology, the compact LEM HAS sensors support a wide measurement range from 50A to 600A, making these transducers suitable for various industrial applications. The HAS series features a voltage output proportional to the measured current, with excellent linearity and low offset drift over temperature. With an instantaneous voltage output of ±4V and a bipolar power supply requirement of ±15V, HAS sensors deliver accurate and efficient current sensing. Additionally, an extended bandwidth of up to 50kHz enables precise monitoring of fast-changing current signals.

Results: 20
Select Image Part # Mfr. Description Datasheet Availability Pricing (CAD) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Accuracy Frequency Range Operating Supply Voltage Output Type
LEM Board Mount Current Sensors Current Transducer HAS 50 ... 600-S. For the electronic measurement of currents: DC, AC, pulsed...,with galvanic separation between the primary circuit and the secondarycircuit. 271In Stock
Min.: 1
Mult.: 1

100 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Current Transducer HAS 50 ... 600-S. For the electronic measurement of currents: DC, AC, pulsed...,with galvanic separation between the primary circuit and the secondarycircuit. 608In Stock
168Expected 2026-03-10
Min.: 1
Mult.: 1

200 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Current Transducer HAS 50 ... 600-S. For the electronic measurement of currents: DC, AC, pulsed...,with galvanic separation between the primary circuit and the secondarycircuit. 133In Stock
Min.: 1
Mult.: 1

400 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
100 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
100 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
200 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
200 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
400 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 63
Mult.: 63
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 14 Weeks
Min.: 84
Mult.: 84
LEM Board Mount Current Sensors Non-Stocked Lead-Time 14 Weeks
Min.: 84
Mult.: 84
200 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 14 Weeks
Min.: 84
Mult.: 84
200 A Current Sense 3 us 1 % 50 kHz 15 V Analog - Voltage
LEM Board Mount Current Sensors Non-Stocked Lead-Time 14 Weeks
Min.: 84
Mult.: 84